From bf2cb0dab8c97f00a71875d9b13dbac17a2f47ca Mon Sep 17 00:00:00 2001
From: NeilBrown <neilb@suse.de>
Date: Fri, 14 Jan 2011 09:14:34 +1100
Subject: [PATCH] md: Fix removal of extra drives when converting RAID6 to
 RAID5

When a RAID6 is converted to a RAID5, the extra drive should
be discarded.  However it isn't due to a typo in a comparison.

This bug was introduced in commit e93f68a1fc6 in 2.6.35-rc4
and is suitable for any -stable since than.

As the extra drive is not removed, the 'degraded' counter is wrong and
so the RAID5 will not respond correctly to a subsequent failure.

Cc: stable@kernel.org
Signed-off-by: NeilBrown <neilb@suse.de>
---
 drivers/md/md.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/md/md.c b/drivers/md/md.c
index 6658513088186..3194a80f36209 100644
--- a/drivers/md/md.c
+++ b/drivers/md/md.c
@@ -3126,7 +3126,7 @@ level_store(mddev_t *mddev, const char *buf, size_t len)
 		char nm[20];
 		if (rdev->raid_disk < 0)
 			continue;
-		if (rdev->new_raid_disk > mddev->raid_disks)
+		if (rdev->new_raid_disk >= mddev->raid_disks)
 			rdev->new_raid_disk = -1;
 		if (rdev->new_raid_disk == rdev->raid_disk)
 			continue;
-- 