Skip to content
Snippets Groups Projects
Commit effb0a80 authored by Javier Carrasco's avatar Javier Carrasco Committed by Frieder Schrempf
Browse files

iio: light: veml6030: fix microlux value calculation


commit 63dd163c upstream.

The raw value conversion to obtain a measurement in lux as
INT_PLUS_MICRO does not calculate the decimal part properly to display
it as micro (in this case microlux). It only calculates the module to
obtain the decimal part from a resolution that is 10000 times the
provided in the datasheet (0.5376 lux/cnt for the veml6030). The
resulting value must still be multiplied by 100 to make it micro.

This bug was introduced with the original implementation of the driver.

Only the illuminance channel is fixed becuase the scale is non sensical
for the intensity channels anyway.

Cc: stable@vger.kernel.org
Fixes: 7b779f57 ("iio: light: add driver for veml6030 ambient light sensor")
Signed-off-by: default avatarJavier Carrasco <javier.carrasco.cruz@gmail.com>
Link: https://patch.msgid.link/20241016-veml6030-fix-processed-micro-v1-1-4a5644796437@gmail.com


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 5faeec2b
No related branches found
No related tags found
Loading
Loading
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment